3516E (50 Hz)

Diesel Generator Sets

Caterpillar is leading the power generation marketplace with Power Solutions engineered to deliver unmatched flexibility, expandability, reliability, and cost-effectiveness.

Show
Standby Rating 3000 kVA (3100 kVA without fan)
Prime Power Rating 2750 kVA (2850 kVA without fan)
Emissions/Fuel Strategy Low Fuel Consumption
Voltage 380 to 11000 volts

Availability Contact Dealer

OVERVIEW

2750 - 3100 kVA Diesel Generator Set

FEATURES & BENEFITS

Cat Generator Set Package

Cat Generator Set PackageCat generator set packages have been fully prototype testedAccepts 100% block load in one step and meets NFPA 110 loading requirementsConform to... Read more

Cat Diesel Engine

Cat Diesel EngineReliable, rugged, durable designField-proven in thousands of applications worldwideFour-stroke-cycle diesel engine combines consistent performance and ex... Read more

SR5 Alternator

SR5 AlternatorSuperior motor starting capability minimizes need for oversizing alternatorDesigned to match performance and output characteristics of Cat diesel enginesRob... Read more

EMCP 4 Control Panel

EMCP 4 Control PanelUser-friendly interface and navigationScalable system to meet a wide range of installation requirementExpansion modules and site-specific programming... Read more

Cooling System

Cooling SystemDesigned to operate in standard ambient temperatures up to 50°C (122°F)Contact your Cat Dealer for specific ambient and altitude capabilities Read more

Certifications

CertificationsEU Declaration of ConformityEU Declaration of IncorporationEurasian Conformity (EAC)Telecommunication Lab of China Read more

One Safe Source

One Safe SourceComponents used in the generator set are selected at the design stage to provide optimum package performanceThe generator set is fully assembled at a Cater... Read more

World Wide Product Support

World Wide Product SupportCat dealers have over 1,800 dealer branch stores operating in 200 countriesYour local Cat dealer provides extensive post-sale support, including... Read more

SPECIFICATIONS FOR 3516E (50 Hz)

Collapse All
Generator Set Specifications
Standby Rating 3000 kVA (3100 kVA without fan)
Prime Power Rating 2750 kVA (2850 kVA without fan)
Emissions/Fuel Strategy Low Fuel Consumption
Voltage 380 to 11000 volts
Frequency 50 Hz
Speed 1500 rpm
Duty Cycle Standby, Mission Critical, Prime
Maximum Rating 3000 kVA (3100 kVA without fan)
Minimum Rating 2750 kVA (2850 kVA without fan)
Engine Specifications
Engine Model 3516E, SCAC, V-16, 4-Stroke, Water-Cooled Diesel
Bore 170 mm
Stroke 215 mm
Displacement 78.1 l
Compression Ratio 14:01
Aspiration TA
Fuel System Electronic unit injection
Governor Type Adem™ A5
Generator Set Dimensions
Length - Maximum 7538 mm
Width - Maximum 2216 mm
Height - Maximum 3391 mm
Dry Weight - Genset (maximum) 19750 kg

SELECT MODELS TO COMPARE

Diesel Generator Sets

DE33 GC (60 Hz)

Maximum Rating 30.0 ekW
Minimum Rating 30.0 ekW
Emissions/Fuel Strategy Non Regulated
Voltage 220 to 480 Volts
Diesel Generator Sets

3516B (50 Hz) India Market Only

Maximum Rating 2250 kVA
Minimum Rating 2000 kVA
Emissions/Fuel Strategy Low Fuel Consumption
Voltage Voltage - Low (415 Volts), Medium and High Voltage
Diesel Generator Sets

3512B (60 Hz) 1500 kW with Upgradeable Package

Standby Rating 1500/1400 kW
Prime Power Rating 1360/1275 kW
Emissions/Fuel Strategy Low Fuel, Low Emissions
Voltage 380 to 480 Volts
Diesel Generator Sets

3516E (50 Hz) High Voltage

Minimum Rating 2750 kVA
Maximum Rating 3000 kVA (3100 kVA without fan)
Voltage 6300 to 11000 volts
Frequency 50 Hz
Diesel Generator Sets

C1.5 | DE13.5E3

Minimum Rating 13.5 kVA
Maximum Rating 13.5 kVA
Diesel Generator Sets

DE88 GC (60 Hz)

Maximum Rating 80 ekW
Minimum Rating 80 ekW
Emissions/Fuel Strategy Non Regulated
Voltage 220 to 480 Volts
Diesel Generator Sets

DE220 GC (50 Hz)

Maximum Rating 217 kVA
Minimum Rating 217 kVA
Emissions/Fuel Strategy Non Regulated
Voltage 380 to 415 Volts
Diesel Generator Sets

CM20C

Minimum Rating 985 kWe
Maximum Rating 1650 kWe
Emissions/Fuel Strategy (WB) Stage 1 and 2
Voltage 3000 to 13800 Volts