3512B (50 Hz) with Upgradeable Package 1600-1875 kVA

Diesel Generator Sets

1600 - 1875 kVA at 50 Hz Diesel GensetThe 3512B generator set has been developed for a wide range of applications, from emergency standby installations such as healthcare and datacenters to continuously powering remote installations. The packages can be optimized for performance that matters to you with either low emissions or low fuel consumption versions available. Backed by the worldwide network of Cat dealers ready to support your operation with technical support, service, parts, and warranty, Cat generator sets will provide the reliability and durability you expect.Q. Does this generator comply with ISO 8528 guidelines?A. Yes, the 3512B, like all of our generators, is tested in accordnace the load steps outlined in with ISO 8528, Part 5.

Show
Standby Rating 1875/1750 kVA
Prime Power Rating 1700/1600 kVA
Emissions/Fuel Strategy Low Fuel , Low Emissions
Voltage 400 to 415 Volts

Availability Contact Dealer

OVERVIEW

1600 - 1875 kVA Diesel Generator Set

FEATURES & BENEFITS

Cat® Diesel Engine

Rugged, durable design with reliable performance proven in thousands of applications worldwideCertified alternative fuels including Hydrotreated Vegetable Oil (HVO), Rene... Read more

Cat Generator Set Package

Accepts 100% block load in one stepMeets NFPA 110 loading requirementsConforms to ISO 8528-5 G3 load acceptance requirementsReliability verified through torsional vibrati... Read more

Alternators

Superior motor starting capability minimizes need for oversizing generatorDesigned to match performance and output characteristics of Cat diesel engines Read more

Cooling System

Cooling systems are available to operate in ambient temperatures up to 50°C (122°F)Tested to ensure proper generator set cooling Read more

EMCP 4 Control Panel

User-friendly interface and navigationScalable system to meet a wide range of installation requirementExpansion modules and site-specific programming for specific custome... Read more

Warranty

24 months/1000-hour warranty for Standby and Mission Critical ratings12 months/unlimited hour warranty for Prime and Continuous ratingsExtended service protection is avai... Read more

Worldwide Product Support

Cat dealers have over 1,800 dealer branch stores operating in 200 countriesYour local Cat dealer provides extensive post-sale support, including maintenance and repair ag... Read more

Financing

Caterpillar offers an array of financial products to help you succeed through financial service excellenceOptions include loans, finance lease, operating lease, working c... Read more

SPECIFICATIONS FOR 3512B (50 Hz) with Upgradeable Package 1600-1875 kVA

Collapse All
Generator Set Specifications
Standby Rating 1875/1750 kVA
Prime Power Rating 1700/1600 kVA
Emissions/Fuel Strategy Low Fuel , Low Emissions
Voltage 400 to 415 Volts
Frequency 50 Hz
Speed 1500 rpm
Duty Cycle Standby, Mission Critical, Prime, Continuous
Minimum Rating 1600 kVA
Maximum Rating 1875 kVA
Engine Specifications
Engine Model 3512B TA, V-12, 4-Stroke Water-Cooled Diesel
Bore 170 mm
Stroke 190 mm
Stroke - HD 215 mm
Displacement 51.8 l
Displacement - HD 58.56 l
Compression Ratio 15.5:1 HD
Aspiration TA
Fuel System Electronic Unit Injection
Governor Type ADEM™ A3
Generator Set Dimensions
Length - Minimum 5404 mm
Length - Maximum 5515 mm
Width - Minimum 2286 mm
Width - Maximum 2286 mm
Height - Minimum 2411 mm
Height - Maximum 2411 mm
Dry Weight - Genset (minimum) 11621 kg
Dry Weight - Genset (maximum) 12034 kg

SELECT MODELS TO COMPARE

Diesel Generator Sets

3616 (50 Hz)

Maximum Rating 7520 kVA
Minimum Rating 4700 kVA
Emissions/Fuel Strategy Low Fuel Consumption
Frequency 50 Hz
Diesel Generator Sets

C280-12

Maximum Rating 3640 ekW (60Hz), 4850 kVA (50Hz)
Minimum Rating 3300 ekW (60Hz), 4400 kVA (50Hz)
Emissions/Fuel Strategy EPA Tier 4 Final, IMO Tier 2
Frequency 50 / 60 Hz
Diesel Generator Sets

Cat® 3516 (50 Hz) with Upgradeable Package

Standby Rating 2000 kVA
Prime Power Rating 1825 kVA
Emissions/Fuel Strategy Low Fuel Consumption
Voltage 380 to 415 Volts
Diesel Generator Sets

3516E (50 Hz) High Voltage

Minimum Rating 2750 kVA
Voltage 6300 to 11000 volts
Frequency 50 Hz
Emissions/Fuel Strategy Low Fuel Consumption
Diesel Generator Sets

3612 (50 Hz)

Maximum Rating 4850 kVA
Minimum Rating 4400 kVA
Emissions/Fuel Strategy Low Fuel Consumption
Frequency 50 Hz
Diesel Generator Sets

Cat® 3516B DGB™ (50 Hz)

Prime Power Rating 2275/2000 kVA
Continuous Rating 2000/1750 kVA
Emissions/Fuel Strategy Low Fuel Consumption
Voltage 380 to 11000 Volts
Diesel Generator Sets

C175-16 (50 Hz)

Standby Rating 3100(no fan)/3000 kVA
Prime Power Rating 2825(no fan)/2725 kVA
Emissions/Fuel Strategy Low Fuel, Low Emissions
Voltage 380 to 11000 Volts
Diesel Generator Sets

3516C (50 Hz)

Standby Rating 2750 kVA
Prime Power Rating 2500 kVA
Emissions/Fuel Strategy Low Fuel, Low Emissions
Voltage 380 to 11000 volts