3516B (50 Hz) 2500 kVA with Upgradeable Package

Diesel Generator Sets

2000 - 2500 kVA at 50 Hz Diesel GensetThe 3516B generator set has been developed for a wide range of applications, from emergency standby installations such as healthcare and datacenters to continuously powering remote installations. The packages can be optimized for performance that matters to you with either low emissions or low fuel consumption versions available. Backed by the worldwide network of Cat dealers ready to support your operation with technical support, service, parts, and warranty, Cat generator sets will provide the reliability and durability you expect.Q. Does this generator comply with ISO 8528 guidelines?A. Yes, the 3516B, like all of our generators, is tested in accordnace the load steps outlined in with ISO 8528, Part 5.

Show
Standby Rating 2500 kVA
Prime Power Rating 2275 kVA
Emissions/Fuel Strategy Low Fuel, Low Emissions
Voltage 380 to 415 Volts

Availability Contact Dealer

OVERVIEW

Genset Diesel 2000 - 2500 kVA

FEATURES & BENEFITS

Cat Generator Set Package

Cat generator set packages have been fully prototype testedAccepts 100% block load in one step and meets NFPA 110 loading requirementsConform to ISO 8528-5 steady state a... Read more

Cat Diesel Engine

Reliable, rugged, durable designField-proven in thousands of applications worldwideFour-stroke-cycle diesel engine combines consistent performance and excellent fuel econ... Read more

SR5 Alternator

Superior motor starting capability minimizes need for oversizing alternatorDesigned to match performance and output characteristics of Cat diesel enginesRobust Class H in... Read more

EMCP 4 Control Panel

User-friendly interface and navigationScalable system to meet a wide range of installation requirementExpansion modules and site-specific programming for specific custome... Read more

Cooling System

Designed to operate in standard ambient temperatures up to 50�C (122�F)Contact your Cat Dealer for specific ambient and altitude capabilities Read more

Certifications

EU Declaration of ConformityEU Declaration of IncorporationEurasian ConformityTelecommunication Lab of China Read more

One Safe Source

Components used in the generator set are selected at the design stage to provide optimum package performanceThe generator set is fully assembled at a Caterpillar facility... Read more

Worldwide Product Support

Cat dealers have over 1,800 dealer branch stores operating in 200 countriesYour local Cat dealer provides extensive post-sale support, including maintenance and repair ag... Read more

SPECIFICATIONS FOR 3516B (50 Hz) 2500 kVA with Upgradeable Package

Collapse All
Generator Set Specifications
Standby Rating 2500 kVA
Prime Power Rating 2275 kVA
Emissions/Fuel Strategy Low Fuel, Low Emissions
Voltage 380 to 415 Volts
Frequency 50 Hz
Speed 1500 rpm
Duty Cycle Standby, Mission Critical, Prime, Continuous
Maximum Rating 2500 kVA
Minimum Rating 2000 kVA
Engine Specifications
Engine Model 3516B TA, V-16, 4-Stroke Water-Cooled Diesel
Bore 170 mm
Stroke 215 mm
Displacement 78 l
Compression Ratio 15.5:1
Aspiration TA
Fuel System Electronic unit injection
Governor Type Adem™3
Generator Set Dimensions
Length - Maximum 6282 mm
Width - Maximum 2286 mm
Height - Maximum 2494 mm
Dry Weight - Genset (maximum) 15535 kg

SELECT MODELS TO COMPARE

Diesel Generator Sets

3516C (50 Hz)

Maximum Rating 3125 kVA
Minimum Rating 2250 kVA
Emissions/Fuel Strategy U.S. EPA Cert., Tier 2 - 1808 rpm
Voltage 380 to 11000 Volts
Diesel Generator Sets

3612 (60 Hz)

Maximum Rating 4000 ekW
Minimum Rating 3300 ekW
Emissions/Fuel Strategy Low Fuel Consumption
Frequency 60 Hz
Diesel Generator Sets

C9 (50 Hz)

Maximum Rating 330 kVA
Minimum Rating 230 kVA
Emissions/Fuel Strategy EU Stage IIIA
Voltage 200 to 400 Volts
Diesel Generator Sets

C280-8

Maximum Rating 2420 ekW (60Hz), 3250 kVA (50Hz)
Minimum Rating 2200 ekW (60Hz), 2938 kVA (50Hz)
Emissions/Fuel Strategy EPA Tier 4 Final, IMO Tier 2
Frequency 50 / 60 Hz
Diesel Generator Sets

DE1250 GC

Minimum Rating 1250 kVA
Maximum Rating 1250 kVA
Emissions/Fuel Strategy Low Fuel Consumption
Voltage 400 - 415 Volts
Diesel Generator Sets

C32 (50 Hz) India Market Only

Maximum Rating 1250 kVA
Minimum Rating 1010 kVA
Emissions/Fuel Strategy Low Fuel Consumption
Voltage 415 Vots
Diesel Generator Sets

3412C (60 Hz)

Maximum Rating 800 ekW
Minimum Rating 635 ekW
Emissions/Fuel Strategy Low Fuel Consumption
Voltage 220 to 480 Volts
Diesel Generator Sets

C15 (60 Hz)

Maximum Rating 500 ekW
Minimum Rating 320 ekW
Emissions/Fuel Strategy Low Fuel, Tier 2, Tier 3, EU Stage IIIA
Voltage 208 to 600 Volts
of