3516B (50 Hz)

Diesel Generator Sets

The 3516B diesel generator sets are made to meet your mission critical, continuous, standby and prime applications. Producing reliable power from 1750 to 2500 kVA at 50 Hz, each generator set has been designed to meet ISO 8528-5 transient response requirements and to accept 100 % rated load in one step. Our integrated control system keeps you connected through on-site and remote monitoring options. We offer easy-to-use EMCP control panel options, combining your management and diagnostic tools in one. The EMCP 4.4 controller provides multi-generator set paralleling capability, giving you the ability to add generator sets to match your growing power requirements. It's not just quality that matters but customization, choose from a broad range of accessories and bolt-on system expansion attachments. Find flexible packaging to fit unique spatial requirements and environmental conditions. Our 3516B generator sets are developed for such prerequisites, so that you can meet your specific power needs.

Show
Standby Rating 2250 kVA
Prime Power Rating 2000 kVA
Emissions/Fuel Strategy Low Fuel, Low Emissions
Voltage 380 to 11000 Volts

Availability Contact Dealer

OVERVIEW

1750 - 2250 kVA Diesel Generator Set

FEATURES & BENEFITS

Cat Generator Set Package

Cat generator set packages have been fully prototype testedAccepts 100% block load in one step and meets NFPA 110 loading requirementsConform to ISO 8528-5 steady state a... Read more

Cat Diesel Engine

Reliable, rugged, durable designField-proven in thousands of applications worldwideFour-stroke-cycle diesel engine combines consistent performance and excellent fuel econ... Read more

SR5 Alternator

Superior motor starting capability minimizes need for oversizing alternatorDesigned to match performance and output characteristics of Cat diesel enginesRobust Class H in... Read more

Cat ECS Control Panel

User-friendly interface and navigationScalable system to meet a wide range of installation requirementExpansion modules and site-specific programming for specific custome... Read more

Cooling System

Designed to operate in standard ambient temperatures up to 50�C (122�F)Contact your Cat Dealer for specific ambient and altitude capabilities Read more

Certifications

IBC seismic certificationEU Declaration of ConformityEU Declaration of IncorporationEurasian Conformity (EAC) Read more

One Safe Source

Components used in the generator set are selected at the design stage to provide optimum package performanceThe generator set is fully assembled at a Caterpillar facility... Read more

Worldwide Product Support

Cat dealers have over 1,800 dealer branch stores operating in 200 countriesYour local Cat dealer provides extensive post-sale support, including maintenance and repair ag... Read more

SPECIFICATIONS FOR 3516B (50 Hz)

Collapse All
Generator Set Specifications
Standby Rating 2250 kVA
Prime Power Rating 2000 kVA
Emissions/Fuel Strategy Low Fuel, Low Emissions
Voltage 380 to 11000 Volts
Frequency 50 Hz
Speed 1500 rpm
Duty Cycle Standby, Mission Critical, Prime, Continuous
Maximum Rating 2250 kVA
Minimum Rating 1750 kVA
Engine Specifications
Engine Model 3516B TA, V-16, 4-Stroke Water-Cooled Diesel
Bore 170 mm
Stroke 190 mm
Displacement 4210.64 l
Compression Ratio 14.0:1
Aspiration TA
Fuel System Electronic unit injection
Governor Type Adem™3
Generator Set Dimensions
Length - Minimum 5928 mm
Length - Maximum 251.7 mm
Width - Maximum 2286 mm
Height - Maximum 2367 mm
Dry Weight - Genset (minimum) 14470 kg
Dry Weight - Genset (maximum) 18290 kg

SELECT MODELS TO COMPARE

Diesel Generator Sets

DE110 GC (50 Hz)

Maximum Rating 110 kVA
Minimum Rating 110 kVA
Emissions/Fuel Strategy Non Regulated
Voltage 380 to 415 Volts
Diesel Generator Sets

C4.4 | DE125AE0

Maximum Rating 100.0 ekW
Minimum Rating 90.4 ekW
Emissions/Fuel Strategy Non-Certified Emissions
Voltage 220 to 380 Volts
Diesel Generator Sets

CM32E

Minimum Rating 3085 kWe
Maximum Rating 4630 kWe
Emissions/Fuel Strategy (WB) Cert stage 1 and 2
Voltage 3000 to 13800 Volts
Diesel Generator Sets

DE400S GC (60 Hz)

Maximum Rating 400 ekW
Minimum Rating 400 ekW
Emissions/Fuel Strategy Low Fuel, R96/EUIIIa
Voltage 220 to 480 Volts
Diesel Generator Sets

C18 (60 Hz)

Maximum Rating 600 ekW
Minimum Rating 455 ekW
Emissions/Fuel Strategy Low Fuel Consumption
Voltage 208 to 600 Volts
Diesel Generator Sets

DE150 GC (50 Hz)

Maximum Rating 150 kVA
Minimum Rating 150 kVA
Emissions/Fuel Strategy Non Regulated
Voltage 380 to 415 Volts
Diesel Generator Sets

C32 (50 Hz) India Market Only

Maximum Rating 1250 kVA
Minimum Rating 1010 kVA
Emissions/Fuel Strategy Low Fuel Consumption
Voltage 415 Vots
Diesel Generator Sets

D300 GC

Maximum Rating 300 ekW
Minimum Rating 300 ekW
Emissions/Fuel Strategy EPA Stationary Emergency
Voltage 208 to 600 Volts