3512B (50 Hz) with Upgradeable Package 1600-1875 kVA

Diesel Generator Sets

The 3512B generator set has been developed for a wide range of applications, from emergency standby installations such as healthcare and datacenters to continuously powering remote installations. The packages can be optimized for performance that matters to you with either low emissions or low fuel consumption versions available. Backed by the worldwide network of Cat dealers ready to support your operation with technical support, service, parts, and warranty, Cat generator sets will provide the reliability and durability you expect.

Show
Standby Rating 1875/1750 kVA
Prime Power Rating 1700/1600 kVA
Emissions/Fuel Strategy Low Fuel , Low Emissions
Voltage 400 to 415 Volts

Ketersediaan Hubungi Dealer

OVERVIEW

1320 - 1750 kVA Diesel Generator Set

FEATURES & BENEFITS

Cat Generator Set Package

Cat generator set packages have been fully prototype testedAccepts 100% block load in one step and meets NFPA 110 loading requirementsConform to ISO 8528-5 steady state a... Read more

Cat Diesel Engine

Reliable, rugged, durable designField-proven in thousands of applications worldwideFour-stroke-cycle diesel engine combines consistent performance and excellent fuel econ... Read more

SR5 Alternator

Superior motor starting capability minimizes need for oversizing alternatorDesigned to match performance and output characteristics of Cat diesel enginesRobust Class H in... Read more

EMCP 4 Control Panel

User-friendly interface and navigationScalable system to meet a wide range of installation requirementExpansion modules and site-specific programming for specific custome... Read more

Cooling System

Designed to operate in standard ambient temperatures up to 50°C (122°F)Contact your Cat Dealer for specific ambient and altitude capabilities Read more

Certifications

EU Declaration of ConformityEU Declaration of IncorporationEurasian Conformity (EAC)Telecommunication Lab of China Read more

One Safe Source

Components used in the generator set are selected at the design stage to provide optimum package performanceThe generator set is fully assembled at a Caterpillar facility... Read more

World Wide Product Support

Cat dealers have over 1,800 dealer branch stores operating in 200 countriesYour local Cat dealer provides extensive post-sale support, including maintenance and repair ag... Read more

SPECIFICATIONS FOR 3512B (50 Hz) with Upgradeable Package 1600-1875 kVA

Collapse All
Generator Set Specifications
Standby Rating 1875/1750 kVA
Prime Power Rating 1700/1600 kVA
Emissions/Fuel Strategy Low Fuel , Low Emissions
Voltage 400 to 415 Volts
Frequency 50 Hz
Speed 1500 rpm
Duty Cycle Standby, Mission Critical, Prime, Continuous
Minimum Rating 1600 kVA
Maximum Rating 1875 kVA
Engine Specifications
Engine Model 3512B TA, V-12, 4-Stroke Water-Cooled Diesel
Bore 170 mm
Stroke 190 mm
Stroke - HD 215 mm
Displacement 51.8 l
Displacement - HD 58.56 l
Compression Ratio 15.5:1 HD
Aspiration TA
Fuel System Electronic Unit Injection
Governor Type ADEM™ A3
Generator Set Dimensions
Length - Minimum 5404 mm
Length - Maximum 5515 mm
Width - Minimum 2286 mm
Width - Maximum 2286 mm
Height - Minimum 2411 mm
Height - Maximum 2411 mm
Dry Weight - Genset (minimum) 11621 kg
Dry Weight - Genset (maximum) 12034 kg

PILIH MODEL UNTUK DIBANDINGKAN

Diesel Generator Sets

3516 (50 Hz) dengan Paket yang Dapat Ditingkatkan

Peringkat Siaga 2000 kVA
Peringkat Daya Utama 1825 kVA
Strategi Emisi/Bahan Bakar Konsumsi Bahan Bakar Rendah
Tegangan 380 hingga 415 Volt
Diesel Generator Sets

3616 (50 Hz)

Peringkat Maksimum 7520 kVA
Peringkat Minimum 4700 kVA
Strategi Emisi/Bahan Bakar Konsumsi Bahan Bakar Rendah
Frekuensi 50 Hz
Diesel Generator Sets

3516B (50 Hz) dengan Paket yang Dapat Ditingkatkan

Peringkat Minimum 1750 kVA
Tegangan 220 hingga 4160 Volt
Frekuensi 50 Hz
Strategi Emisi/Bahan Bakar Bahan bakar rendah, Emisi Rendah
Diesel Generator Sets

3512B (CTL)

Peringkat Minimum 1230 ekW
Peringkat Maksimum 1500 ekW
Tegangan 220 hingga 13.800 Volt
Frekuensi 60 Hz
Diesel Generator Sets

3512B (50 Hz)

Peringkat Siaga 1875/1750/1600/1500 kVA
Peringkat Daya Utama 1700/1600/1500/1360 kVA
Strategi Emisi/Bahan Bakar Bahan Bakar Rendah, Emisi Rendah
Tegangan 380 hingga 415 Volt
Diesel Generator Sets

C4.4 (60 Hz)

Peringkat Maksimum 60 ekW
Peringkat Minimum 36 ekW
Strategi Emisi/Bahan Bakar Sertifikasi EPA AS, Tier 3
Tegangan 208 hingga 600 Volt
Diesel Generator Sets

C175-20 (50 Hz)

Peringkat Siaga 4000 (tanpa kipas)/3900 kVA
Peringkat Daya Utama 3600 (tanpa kipas)/3500 kVA
Strategi Emisi/Bahan Bakar Bahan Bakar Rendah, Emisi Rendah
Tegangan 3300 hingga 11000 Volt
Diesel Generator Sets

3516E (50 Hz) Tegangan Tinggi

Peringkat Minimum 2750 kVA
Tegangan 6300 hingga 11000 volt
Frekuensi 50 Hz
Strategi Emisi/Bahan Bakar Konsumsi Bahan Bakar Rendah
of
01
KIRIM PERMINTAAN

Pilih Produk Yang Anda Cari Lalu isi Data Diri Anda Untuk Bisa Kami Hubungi

02
DAPATKAN PENAWARAN

Representative Kami Akan Mengirimkan Penawaran dan Informasi Yang Berhubungan

03
PENGIRIMAN & PEMBAYARAN

Lakukan Pembayaran– Pilih Pengiriman - Pengiriman

Pilih Maksimal
3 Model Untuk Dibandingkan
Model 1
Model 2
Model 3