CM25E

Diesel Generator Sets

Caterpillar electric power stands for reliable energy supply. Especially during the energy system transformation, Cat generator sets close the energy gap caused by renewable energy source such as wind and photo voltaic. Short ramp up time, low operating costs and rapid maintenance times ensures a high availability according to the need of our customers. Combined heat /cool and power solutions allow our customers to maximize the efficiency and earnings paired with low emissions. Wherever power is needed around the globe, Caterpillar is able to support you with the best products and services to maximize your profit.

Show
Minimum Rating 1940 kWe
Maximum Rating 2910 kWe
Emissions/Fuel Strategy (WB) Cert stage 1 and 2
Voltage 3000 to 13800 Volts

Availability Contact Dealer

OVERVIEW

CM25E

FEATURES & BENEFITS

Reliable Operation

Intensive cooling of key components including exhaust valve seats, injector cooling integrated into lube oil systemReliable, proven and high efficient single turbo chargi... Read more

Control & Monitoring

Ultrafast start time and load acceptanceNo engine start limitationsContinuous power (base and peak load), prime power, stand-byPart load with high efficiencyMonitoring fo... Read more

Ease Of Installation

Reduced complexity of standard modular design allows an easy installationLow space requirements between the gensetsGenset is ready for installationGenerator set designed... Read more

Ease Of Operation

Low fuel and oil consumptionLow maintenance requirementsOperator and maintenance training courses available Read more

Intelligent Simplicity

High reliability, modular design and integral construction reduce the number of components by 40% over conventional designs e.g.:- Dry engine block with integrated ducts... Read more

Ease Of Maintenance

Smart maintenance solutions allow an easy component accessibilityLarge inspection openings afford an easy serviceability to core engine internalsCore engine components de... Read more

Fuel

Liquid: Light fuel oil (LFO), crude oil and heavy fuel oil (HFO) with fuel quality up to 700 cSt/50°C according to CIMAC H55/K55Dual:- Light fuel oil (LFO), crude oil and... Read more

Emissions

World bank emission certification (Stage 2)Technische Anleitung (TA) Luft (only gas)Post-emission treatment systems for lower emission requirements available Read more

Expertise & Experience

Assistance for planning - delivery - commissioning - operation and service)Expertise and experience for solutions to maximize benefits, e.g. combine heat and power system... Read more

SPECIFICATIONS FOR CM25E

Collapse All
Generator Set Specifications
Minimum Rating 1940 kWe
Maximum Rating 2910 kWe
Emissions/Fuel Strategy (WB) Cert stage 1 and 2
Voltage 3000 to 13800 Volts
Frequency At Speed 50 Hz @ 750 / 60 Hz @ 720
Duty Cycle Prime, Continuous
Ready To Accept Loads (Preheated/Vented) 40 s
Normal Ramp Up To 100% Load 85 s
Emergency Ramp Up 10% To 100% Load 30 s
Genset Efficiency Up To 43.50%
Engine Specifications
Engine Model CM25, 4-stroke-engine
Bore 255 mm
Stroke 400 mm
Aspiration Turbocharged-aftercooled
Engine Rating Range 2010 - 3015 kW
Configuration 6,8,9 cylinder
Fuel Type Diesel oil / heavy fuel oil (HFO) / crude oil
Swept Volume 20.4 l/cyl
Mean Effective Pressure Up To 27.3 bar
Specific Fuel Oil Consumption (WB I) Up To 187 g/kWh
Specific Fuel Oil Consumption (WB II) Up To 187 g/kWh
Specific Lube Oil Consumption 0.6 g/kWh
Generator Set Dimensions
Length - Minimum 7717 mm
Length - Maximum 8713 mm
Width - Minimum 2357 mm
Width - Maximum 2357 mm
Height - Minimum 3866 mm
Height - Maximum 4066 mm
Dry Weight - Genset (minimum) 43 ton (US)
Dry Weight - Genset (maximum) 56 ton (US)

SELECT MODELS TO COMPARE

Diesel Generator Sets

3606 (50 Hz)

Maximum Rating 2688 kVA
Minimum Rating 1775 kVA
Emissions/Fuel Strategy Low Fuel Consumption
Frequency 50 Hz
Diesel Generator Sets

3516 (60 Hz)

Standby Rating 1750 ekW
Prime Power Rating 1600 ekW
Emissions/Fuel Strategy Low Fuel, Low Emissions
Voltage 380 to 13800 Volts
Diesel Generator Sets

DE350S GC (60 Hz)

Maximum Rating 350 ekW
Minimum Rating 350 ekW
Emissions/Fuel Strategy Low Fuel, R96/EUIIIa
Voltage 220 to 480 Volts
Diesel Generator Sets

C13 (60 Hz)

Maximum Rating 400 ekW
Minimum Rating 320 ekW
Emissions/Fuel Strategy EPA Stationary Emerg Use
Voltage 208 to 600 Volts
Diesel Generator Sets

C18 (50 Hz) India Market Only

Maximum Rating 600 kVA
Minimum Rating 600 kVA
Emissions/Fuel Strategy India CPCB/MoEF
Voltage 415 Volts
Diesel Generator Sets

C32 (50 Hz) India Market Only

Maximum Rating 1250 kVA
Minimum Rating 1010 kVA
Emissions/Fuel Strategy Low Fuel Consumption
Voltage 415 Vots
Diesel Generator Sets

D300 GC

Minimum Rating 250 ekW
Maximum Rating 300 ekW
Emissions/Fuel Strategy Tier 3
Voltage 208 to 600 Volts
Diesel Generator Sets

DE220 GC (50 Hz)

Maximum Rating 217 kVA
Minimum Rating 217 kVA
Emissions/Fuel Strategy Non Regulated
Voltage 380 to 415 Volts