MENU
BUY PARTS
REQUEST QUOTE
FIND LOCATION
back
to top
Back to listing page

CM20C

Diesel Generator Sets

Caterpillar electric power stands for reliable energy supply. Especially during the energy system transformation, Cat generator sets close the energy gap caused by renewable energy source such as wind and photo voltaic. Short ramp up time, low operating costs and rapid maintenance times ensures a high availability according to the need of our customers. Combined heat /cool and power solutions allow our customers to maximize the efficiency and earnings paired with low emissions. Wherever power is needed around the globe, Caterpillar is able to support you with the best products and services to maximize your profit.

Show
Minimum Rating 985 kWe
Maximum Rating 1650 kWe
Emissions/Fuel Strategy (WB) Stage 1 and 2
Voltage 3000 to 13800 Volts

Availability Contact Dealer

OVERVIEW

CM20C

FEATURES & BENEFITS

Reliable Operation

Intensive cooling of key components including exhaust valve seats, injector cooling integrated into lube oil systemReliable, proven and high efficient single turbo chargi... Read more

Control & Monitoring

Ultrafast start time and load acceptanceNo engine start limitationsContinuous power (base and peak load), prime power, stand-byPart load with high efficiencyMonitoring fo... Read more

Ease Of Installation

Reduced complexity of standard modular design allows an easy installationLow space requirements between the gensetsGenset is ready for installationGenerator set designed... Read more

Ease Of Operation

Low fuel and oil consumptionLow maintenance requirementsOperator and maintenance training courses available Read more

Intelligent Simplicity

High reliability, modular design and integral construction reduce the number of components by 40% over conventional designs e.g.:- Dry engine block with integrated ducts... Read more

Ease Of Maintenance

Smart maintenance solutions allow an easy component accessibilityLarge inspection openings afford an easy serviceability to core engine internalsCore engine components de... Read more

Fuel

Liquid: Light fuel oil (LFO), crude oil and heavy fuel oil (HFO) with fuel quality up to 700 cSt/50°C according to CIMAC H55/K55Dual:- Light fuel oil (LFO), crude oil and... Read more

Emissions

World bank emission certification (Stage 2)Technische Anleitung (TA) Luft (only gas)Post-emission treatment systems for lower emission requirements available Read more

Expertise & Experience

Assistance for planning - delivery - commissioning - operation and service)Expertise and experience for solutions to maximize benefits, e.g. combine heat and power system... Read more

SPECIFICATIONS FOR CM20C

Collapse All
Generator Set Specifications
Minimum Rating 985 kWe
Maximum Rating 1650 kWe
Emissions/Fuel Strategy (WB) Stage 1 and 2
Voltage 3000 to 13800 Volts
Frequency At Speed 50 Hz @ 1000 / 60 Hz @ 900
Duty Cycle Prime, Continuous
Ready To Accept Loads (Preheated/Vented) 40 s
Normal Ramp Up To 100% Load 75 s
Emergency Ramp Up 10% To 100% Load 25 s
Genset Efficiency Up To 43.10%
Engine Specifications
Engine Model CM20C, 4-stroke-engine
Bore 200 mm
Stroke 300 mm
Aspiration Turbocharged-aftercooled
Engine Rating Range 1020 - 1710 kW
Configuration 6,8,9 cylinder
Fuel Type Diesel oil / heavy fuel oil (HFO) / crude oil
Swept Volume 9.4 l/cyl
Mean Effective Pressure Up To 24.2 bar
Specific Fuel Oil Consumption (WB I) Up To 189 g/kWh
Specific Fuel Oil Consumption (WB II) Up To 189 g/kWh
Specific Lube Oil Consumption 0.6 g/kWh
Generator Set Dimensions
Length - Minimum 6073 mm
Length - Maximum 7125 mm
Width - Minimum 1680 mm
Width - Maximum 1816 mm
Height - Minimum 2833 mm
Height - Maximum 3010 mm
Dry Weight - Genset (minimum) 18.8 ton (US)
Dry Weight - Genset (maximum) 30 ton (US)

SELECT MODELS TO COMPARE

Diesel Generator Sets

C4.4 (50 Hz)

Maximum Rating 110 kVA
Minimum Rating 50 kVA
Emissions/Fuel Strategy EU Stage II & R96/EUIIIa
Voltage 110 to 480 Volts
Diesel Generator Sets

DE33 GC (50 Hz)

Maximum Rating 33.0 kVA
Minimum Rating 33.0 kVA
Emissions/Fuel Strategy Non Regulated
Voltage 380 to 415 Volts
Diesel Generator Sets

C3.3 (50 Hz)

Maximum Rating 65.0 kVA
Minimum Rating 24.0 kVA
Emissions/Fuel Strategy EU Stage II R96/EUIIIa
Voltage 110 to 480 Volts
Diesel Generator Sets

D500 GC (60 Hz)

Maximum Rating 500 ekW
Minimum Rating 500 ekW
Emissions/Fuel Strategy EPA Stationary Emergency
Voltage 480 to 600 Volts
Diesel Generator Sets

3608 (60 Hz)

Maximum Rating 2660 ekW
Minimum Rating 1830 ekW
Emissions/Fuel Strategy Low Fuel Consumption
Frequency 60 Hz
Diesel Generator Sets

D250 GC

Maximum Rating 250 ekW
Minimum Rating 250 ekW
Emissions/Fuel Strategy EPA Stationary Emergency
Voltage 208 to 600 Volts
Diesel Generator Sets

C15 | 500 kVA (50 Hz)

Maximum Rating 500 kVA
Minimum Rating 500 kVA
Emissions/Fuel Strategy India CPCB/MoEF
Voltage 415 Volts
Diesel Generator Sets

C3.3 | DE55 GC

Frequency 60 Hz
Maximum Rating 50 ekW
Emissions/Fuel Strategy Non Regulated
Voltage 220 to 480 Volts
of
01
SEND REQUEST

Select your equipment and fill out your contact information

02
GET A QUOTE

A sales rep will send you an official quote and other related information

03
PAYMENT & DELIVERY

Payment – Lead time - Delivery

Select Up to
3 Models to Compare
Model 1
Model 2
Model 3