3516B

Marine Generator Sets

The 3516B Marine Generator Set incorporates a separate circuit aftercooling (SCAC) or sea water aftercooling (SWAC) system for all configurations. The primary advantage of the SCAC systsem is reduced aftercooler corrosion since no sea water circulates through the aftercooler. Many other improvements on these engines contribute to minimizing owning and operating costs. A strengthened fuel injection actuation system and rear gear train maintain reliability and durability while providing higher injection pressures. The 3516B also features thermo-laminated heat shields on all marine configurations to maintain surface temperatures below Marine Classification Society regulations.

Show
Minimum Rating 1180 eKW (1475 kVA)
Maximum Rating 1825 eKW (2281 kVA)
Frequency 50 Hz or 60 Hz
Speed 1000 rpm, 1200 rpm, 1500 rpm, 1800 rpm

Availability Contact Dealer

SPECIFICATIONS FOR 3516B

Collapse All
Generator Set Specifications
Minimum Rating 1180 eKW (1475 kVA)
Maximum Rating 1825 eKW (2281 kVA)
Frequency 50 Hz or 60 Hz
Speed 1000 rpm, 1200 rpm, 1500 rpm, 1800 rpm
Emissions/Fuel Strategy IMO I, IMO II (1600 eKW @ 50 hz only)
Engine Specifications
Configuration Vee 16, 4-Stroke-Cycle Diesel
Bore 170 mm
Stroke 190 mm
Displacement 69 l
Generator Set Dimensions
Weight 11354 kg (25030 lb) to 13538 kg (29845 lb)
Length 5076 mm (199.8 in) to 5611 mm (220.9 in)
Width 1703 mm (67.1 in) to 2144 mm (84.4 in)
Height 2053 mm (80.8 in) to 2100 mm (82.7 in)

SELECT MODELS TO COMPARE

Marine Generator Sets

C4.4 ACERT

Minimum Rating 58R ekW (50 Hz), 51R ekW (60 Hz)
Maximum Rating 88R ekW (50 Hz), 105R ekW (60 Hz)
Frequency 50 Hz or 60 Hz
Speed 1500 rpm or 1800 rpm
Marine Generator Sets

C1.5

Minimum Rating 10 ekW (10 kVA)
Maximum Rating 12 ekW (12 kVA)
Frequency 50 Hz or 60 Hz
Speed 1500 / 1800 rpm
Marine Generator Sets

C18 (SRMP) Marine Generator Set

Minimum Rating 260 ekW (325 kVA)
Maximum Rating 565 ekW (706 kVA)
Frequency 50 hz
Speed 50 Hz - 1500 rpm, 60 Hz - 1800 rpm
Marine Generator Sets

C32 IMO III

Minimum Rating 219 ekW
Maximum Rating 940 ekW
Frequency 60hz
Rated Engine Speed 1500 rpm
Marine Generator Sets

3508B

Minimum Rating 590 eKW (738 kVA)
Maximum Rating 910 eKW (1138 kVA)
Frequency 50 hz or 60 hz
Speed 1000 rpm, 1200 rpm, 1500 rpm, 1800 rpm
Marine Generator Sets

C18 ACERT IMO II

Minimum Rating 330 ekW (418 kVA)
Maximum Rating 450 ekW (563 kVA)
Frequency 50 Hz or 60 Hz
Speed 1500 rpm (50 hz) or 1800 rpm (60 hz)
Marine Generator Sets

C32 Tier 3 / IMO II

Minimum Rating 219 ekW
Maximum Rating 940 ekW
Frequency 60hz
Rated Engine Speed 1800 rpm
Marine Generator Sets

C280-8

Minimum Rating 2350 ekW (2938 kVA)
Maximum Rating 2420 ekW (3025 kVA)
Frequency 50 Hz or 60 Hz
Speed 1000 rpm (50 hz) or 900 rpm (60 hz)